Rotator Flow Meter (GPE 2001)
ROTATOR FLOW METER
The F2001 Bi-Rotator Flow Meter is a positive displacement meter utilized in the most demanding applications requiring accuracy, long life and ruggedness. It owns two precise machined helical rotators which share the same size. The two rotators rotate together at the same speed in the measuring chamber and divide the flowing stream into segments with equal volume which is precisely designed, and the segments will join back into one stream on the outlet side of the FlowMeter. By counting the segments through the meter, the flow can be calculated. The rotationstatus is transferred to the totalizing register or the transmitter for recording and calculation. Volume indication is determined by mechanical output gearing leading to mechanical register and F9005 Signal Generator.High accuracy is attained by two unique helical rotators which feature two finely balanced rotaters (Refer to Figure 1). An adjustor, incorporated on the meter, is used to assure maximum accuracy within the meters flow range.
Features:
- Accuracy up to 0.1%, over 10:1 turn-down ratio
- Extremely long service life and easy maintenance
- Self-lubricating, low pressure drop, and low noise and vibration
- Two unique helical rotators with no touch, but synchronized by timing gears in the measuring chamber
- No oscillating, reciprocating or sliding parts or cranks to wear or disturb the balanced rotary action
Specification:
- Accuracy: 0.1% of reading accuracy
- Line size : " to 16" (8 to 400mm)
- Repeatability: 0.02%
- Working Pressure: Customized
- Pulse Output: (18 to 36V, VH=20V,) VL<1V and output load 200 )
- Process temperature: - 22 to 480 F (-30 to 250 )
- Current Output: 4 to 20mA, (two wire system w/ 600 max loop load)
- RS485 Output: communication with Modbus
- Viscosity: 0 to 20,000 cP
- RTU (powered by 18 to 36V and <60mA)
- Protection: IP 65( IP67 for option)
- Display: Instantaneous / Total / Batch flow
- Ambient Temperature: -4 to 131 F(-20 to +55 )
- Ambient Humidity: 5% to 95% RH @ 75 F
- User Parameters: K factors, linear correction coefficient flowrate input signal section points, temperature and
- pressure compensation, set pulse output range, decimal adjustment, etc.
- Communication Baud Rate: Optional (1200 ,2400, 4800 or 9600)
Materials of Construction:
- Housing: Welded Steel Construction CombiningSteel Castings and Drawn Steel Plate
- Rotators: Three/Four Lobe Rotator - Cast Iron/SS304/ SS316/ SS420
- Measuring Chamber: Cast Iron/SS304/SS316
- Rotator Shafts: E.T.D. 150
- Rotator Bearings: Stainless Steel (Standard) , other materials (Optional)
- Body and End Covers: Cast Iron, Cast Steel,SS304, SS316
- Counter Base Plate: Cast Steel
- Body: Cast iron, Cast steel, SS304,SS316
- O-Ring: Viton (Standard)